It collects dust and is almost impossible to clean.
Change sheet metal duct to flex.
Flexible duct can degrade over time.
More than likely.
Bob s not a fan of flexible heating ductwork.
There s no question that flexible duct is easier to install than metal ductwork but consider this.
Ryan shanahan i ve been told to avoid using metal screws with flex duct because the flex can tear easily once you create a hole.
Metal ducts are more rigid due to the nature of steel making them ideal to build an entire hvac system.
Flexible duct needs to be larger than pipes to allow the same amount of airflow.
You may need to buy a sheet metal fitting to properly connect the correct size of flex duct to the hard duct.
The sample from above calculates out to 7 inch for flex duct size.
Here are the itemized costs for the most common types of ductwork and supplies needed to complete installation.
You can even use three sheet metal screws behind the first rib or two of the duct as long as you use mastic under the duct at the sheet metal connection.
Flexible duct connector designed to isolate equipment noise and vibration from the ductwork proflex flexible duct connector consists of a fabric which is secured to sheet metal on both sides.
1 10 5 25 per foot insulated flexible duct 4 to 16 diameters used as branches or in radial duct attic systems 2 30 13 00 per foot round and oval sheet metal duct 3 to 8 diameters typically used for trunks in small homes and.
Typically the connector is inserted between the equipment and the ductwork.
If you have had problems with holes or cracks in the past this may be a good choice.
Cost of installation supplies.
The flex duct size may be different than the hard duct that runs to that room.
Flexible aluminum ducting is slightly more expensive and less prone to tearing.
Unscrew any sheet metal screws connecting metal duct to a boot or another section of duct.
Most often flex duct is used to reduce cost or in places where metal duct work will not fit.
Online residential ductulator.
Pull the duct from the boots and set it aside to either be thrown away or recycled.
Flex ducts are better for existing trunk and branch heating and cooling systems.
Sheet metal the strongest material costs more than non metallic or flexible aluminum ducting with additional labor costs for multiple turns.
In comparison to metal duct flex duct is easier and faster to install.
You mentioned that you were considering re insulating your current metal duct work.
This is because they re more versatile and flexible.